contactor labored basic principle : when the contactor coil is energized, the coil recent will produce a magnetic area,
The produced magnetic subject can make the static iron main generate electromagnetic attraction to entice the relocating iron core, and drives the AC contactor position to act. The typically shut get in touch with is open, and the typically open make contact with is closed. The two are joined. When the coil is de energized, the electromagnetic attraction disappears, and the armature is introduced below the motion of the release spring, so that the get in touch with is restored, the normally open up contact is opened, and the typically closed speak to is shut. The working principle of DC contactor is comparable to that of temperature swap
LC1-D  5011  Three stage protactor contactor cost for electricity capacitor 
The series JKC1 AC contactor is applicable at the line of AC 50/60 Hz, rated voltage up to 660V and rated present up to 95A for remote swap, breaking and frequent starting, managing the AC motor. In addition, the contactor can act as the time-hold off contactor, reve-rsible contactor, star-delta starter by the components addition this sort of as addition of modular auxiliary contact established. Air timedelay head, mechanical interlock system, and so on. Moreover, it could act as the electromagnetic starter by the immediate plug of the thermal relay.

This item conforms to the necessity of IEC60947-four-one& GB14048.four standards.

Type Rated
insulation
voltage(V)
Traditional
thermal
recent(A)
Rated
procedure
current(A)
Manage electrical power(kw) No .of
contacts
Remark
220V 380V 415V 440V 660V
JKC1-571
0571
 
660 twenty 9 two.two 4 4 4 5.five 3P+NO
3P+NC
 
Set up
technique
one.with two
screws
two.35mm
din rail
JKC1-1200
1201
 
twenty twelve 3 five.5 5.five 5.5 7.five 3P+NO
3P+NC
 
JKC1-1810
1801
 
32 18 four 7.five nine nine 9 3P+NO
3P+NC
 
JKC1-2510
2501
 
40 25 five.5 11 eleven 11 15 3P+NO
3P+NC
 
JKC1-3210
3201
 
50 32 7.five fifteen fifteen 15 18.five 3P+NO
3P+NC
 
JKC1-4011 60 forty eleven eighteen.5 22 22 thirty 3P+NO+NC Set up
method
one.with a few
screws
2.75mm or
35mm
din rail
JKC1-5011 80 50 fifteen 22 25 30 33
JKC1-6511 80 65 18.five thirty 37 37 37
JKC1-8011 one hundred twenty five 80 22 37 forty five forty five 45
JKC1-9511 a hundred twenty five 95 twenty five 45 45 45 forty five

Variety JKC1-09 JKC1-twelve JKC1-18 JKC1-twenty five JKC1-32 JKC1-40 JKC1-50 JKC1-sixty five JKC1-eighty JKC1-ninety five
Choose-up voltage
fifty/60Hz(V)
(.eighty five~
1.1)Us
(.85~
one.one) Us
(.eighty five~
one.one)Us
(.eighty five~
1.one)Us
(.eighty five~
1.1)Us
(.eighty five~
one.1)Us
(.85~
1.1)Us
(.85
~1.1)Us
(.eighty five~
1.one)Us
(.eighty five~
1.1)Us
Release voltage
fifty/60Hz(v)
(.two~
.seventy five)Us
(.2~
.75)Us
(.2~
.75)Us
(.two~
.seventy five)Us
(.two~
.seventy five)Us
(.2~
.75)Us
(.two~
.75)Us
(.2~
.75)Us
(.two~
.seventy five)Us
(.two~
.75)Us
Coil power 50Hz

60Hz
 
 

Select-up(VA) 70 70 one hundred ten 110 a hundred and ten 200 200 two hundred two hundred 200
Holding(VA) 8 eight eleven eleven 11 20 20 twenty 20 20
Choose-up(VA) 80 eighty one hundred fifteen one hundred fifteen one hundred fifteen two hundred 200 200 two hundred two hundred
Holding(VA) 8 eight eleven eleven 11 20 twenty twenty 20 twenty
Electricity
intake
(W)
1.eight~2.seven 1.8~2.seven three~4 3~4 3~four 6~ten six~ten six~10 6~10 6~10

 